kx1 test and alignment part I

kc5wa
On pg 28 right coluum 2nd step:
checking AC measurements using DMM
~~~~~~~~~~~~~~~~~~~~~~~~~~
Should an RF probe be used.
Instructions do not state either way
tnx  de "rc" kc5wa

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

RE: kx1 test and alignment part I

Ron D'Eau Claire-2
RC KC5WA asked:
On pg 28 right coluum 2nd step:
checking AC measurements using DMM
~~~~~~~~~~~~~~~~~~~~~~~~~~
Should an RF probe be used.
Instructions do not state either way.

---------------------------------


No. The oscillation you are checking for would be in the normal a-c range of
your DMM. That's why the instructions say to probe those points with your
DMM in the 200 to 300 millivolt a-c range.

RF probes rectify the signal and provide a d-c level for the meter to
indicate. Most RF probes have resistors in them to produce a d-c reading on
the meter equivalent to the RMS voltage of the RF signal - assuming a good
sinusoidal waveform.

Ron AC7AC



_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com