resistances test K2

classic Classic list List threaded Threaded
2 messages Options
Reply | Threaded
Open this post in threaded view
|

resistances test K2

Christophe F8ACF-56

Good evening to all,

I just finished my board control my K2.

resistance tests on page 22 of the manual.

 I have my doubts about 3 steps "Q1 collector" we must have:> 1 million, I think infinity is this normal?

"U6 pin 29 and pin 30" I should have between 70 to 90 K, 95 K I is critical?
thank you for your answers

K2 # 7369

 
73 , Christophe F8ACF-56
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: resistances test K2

Mike K8CN
Hi Christophe,

Your resistance values are fine.  These control board resistance checks are intended to reveal low resistance paths that should not be present (for example, solder bridges), and your measured values are far from short circuits!

Enjoy the building of your K2.....

73,
Mike, K8CN