Re: K3 - SWR Indication
Posted by
Geoffrey Downs-2 on
May 04, 2009; 4:48pm
URL: http://elecraft.85.s1.nabble.com/K3-SWR-Indication-tp2784793p2788264.html
----- Original Message -----
From: "Steve Ellington" <
[hidden email]>
> Geoff
> Try putting a 50 ohm dummy load in line and see if the K3 and your ext.
> meters read the same swr. This will take reactance and inbalance out of
> the picture.
Thanks Steve. I did try that and with a 50 ohm dummy load all three meters
show the same 1.0:1 SWR. It seems that the K3 meter responds differently
from the other two to reactance in the load.
73 to all
Geoff
G3UCK