L1 vs W1 Power Reading
Posted by
akiwi ham on
May 09, 2009; 7:20pm
URL: http://elecraft.85.s1.nabble.com/L1-vs-W1-Power-Reading-tp2851144.html
I recently put together a DL1 dummy load and W1 wattmeter.
I have the DL1 connected to my KX1 through the W1. I have the W1 connected
to a computer using the W1 software. I have a significant difference between
the power reading from the W1 and the power calculated from the voltage
measured on TP1 of the DL1 using a digital volt meter.
For example:
W1 reading = 4.04W
TP1 volts on DL1 = 8.97V => 3.29W
Is this magnitude of difference to be expected?
Bryan, Zl1NI
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]
This list hosted by:
http://www.qsl.netPlease help support this email list:
http://www.qsl.net/donate.html