Login  Register

Re: Oscilloscopes

Posted by George & Jan on May 21, 2009; 8:39pm
URL: http://elecraft.85.s1.nabble.com/Oscilloscopes-tp2953989p2954077.html

Depends on your definition significant.

I had both in a shop and both preformed well for almost all applications. At
DC, audio or video they were virtually identical. At high speed data in the
10 to 150 mbs range the 475 was preferred. RF over 50 MHz the 475 was
better.
The 475 has slightly better specs for the time base and a wider bandwidth.
It was better in measuring time at below microsecond range and had time base
lower jitter.

------------

Is there a significant difference between the 465 and the 475?

K4GM- George

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html