Wouldn't the peak signal be 1.4 times the RMS value of a steady CW signal.
If S-meter is saving signal peaks rather than the "average", it should read
just a tiny bit higher.

73, Guy.

On Fri, Aug 14, 2009 at 6:58 AM, David Pratt <[hidden email]>wrote:

> Yesterday, I mentioned that my S-meter was showing S9+5dB with an input
> of 50uV after calibrating with the K3 Utility.
>
> I normally have CONFIG: SMTR PK On.  But I notice that if I toggle SMTR
> PK OFF the S-meter goes down an S-point.  Hence, with SMTR PK OFF my
> S-meter now reads S9.
>
> But should toggling SMTR PK make any difference to the S meter reading
> with a constant signal?
>
> 73
> --
> David G4DMP
> Leeds, England, UK
> ------
>
>
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[hidden email]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
>



--
73, Guy  K2AV