Login  Register

K2 PLL Oscillator Range Test failure (barely)

Posted by ne1rd on Jan 03, 2005; 4:33pm
URL: http://elecraft.85.s1.nabble.com/K2-PLL-Oscillator-Range-Test-failure-barely-tp373202.html

On page 60 of the K2 manual the PLL Reference Oscillator Range Test
asks for the Ref. High Freq. and Ref. Low Freq. measurements. I have

HI = 12099.67
LO = 12090.50
DIFF 9.17

which is less than the 9.8 to 15 kHz required by the manual.
Everything else looks good. Any ideas? Any help would be
appreciated. Thanks.

-- Scott (NE1RD)

PS What a beautiful kit. I'm loving it!

B. Scott Andersen    | "Magic is real, unless declared integer."
[hidden email]   | -- The collected sayings of Wiz Zumwalt
Acton, Massachusetts | Ham: NE1RD, QRP ARCI#11588, FP#-910