Re: K2/100 current consumption problem - update

Posted by Vic K2VCO on
URL: http://elecraft.85.s1.nabble.com/K2-100-current-consumption-problem-tp375119p375126.html

Fraser Robertson wrote:

>  One thing; C83 is
> 1000pF, not 1200pF as per circuit.  However I tried padding that with a
> 220pF SM and it made no difference.  Looks like 1000pF was supplied with
> the kit.

Hi Fraser,

The change from 1200 to 1000 was made after the field test.  It improves
efficiency on 10 meters.  It shouldn't have any effect on 160.  1000 is correct.

I admit to being mystified by your problem!

--
73,
Vic, K2VCO
Fresno CA
http://www.qsl.net/k2vco

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com