Re: K2 Relay contact resistance
Posted by
N2EY on
Feb 12, 2006; 6:45pm
URL: http://elecraft.85.s1.nabble.com/K2-Relay-contact-resistance-tp386534p386542.html
In a message dated 2/12/06 12:07:24 PM Eastern Standard Time,
[hidden email] writes:
> K2 s/n 12 in pretty constant use here, particularly in contests.
> So far as I can tell, I have no problem with the relays, either in the
> basic K2 or in the KAT2.
>
Perhaps that 'pretty constant use' is the key.
IIRC, the original poster said he "dusted off his '1000MP". Which means it
has probably been sitting around idle for a long time.
Wiping action only works if the relays actually cycle once in a while.
73 de Jim, N2EY
_______________________________________________
Elecraft mailing list
Post to:
[hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help:
http://mailman.qth.net/subscribers.htmElecraft web page:
http://www.elecraft.com