Posted by
Ron D'Eau Claire-2 on
May 21, 2006; 2:09am
URL: http://elecraft.85.s1.nabble.com/K2-AGC-Off-Problem-tp389830p389833.html
No. Changing that cap only affects the heterodyne oscillator for the AGC and
nothing else. As long as the oscillator comes on and off on command (AGC On
and Off work properly) you're FB.
Ron AC7AC
-----Original Message-----
From:
[hidden email]
[mailto:
[hidden email]] On Behalf Of Darrell Bellerive
Sent: Saturday, May 20, 2006 5:50 PM
To:
[hidden email]
Subject: Re: [Elecraft] K2 AGC Off Problem
Ken,
Thanks for the message.
A 10 pf at C8 did the trick. The receiver is now working properly in AGC off
mode.
What are the implications of this substitution? Does changing C8 from 39 pf
to
10 pf cause any other problems?
Since I robbed the 10 pf from it's future spot in the 10 meter low pass
filter, a replacement part is needed in any case. Is it better to replace
X1,
and go back to the original 39 pf capacitor, or should I just get another 10
pf for the low pass filter and leave the 10 pf at C8?