Colin,
My K2 #3255 shut down one day when about 2-1/2 years old leaving the display
showing the frequency last used, but none of the front panel controls
functioning except the power ON-OFF switch. After an overnight rest all was
well. Eventually I found the problem to be caused by the socket of the
Control Board MCU, perhaps a bit of corrosion, and later I replaced the
socket with a turned pin type for a lasting solution.
73,
Geoff
GM4ESD
C WEAVING
[hidden email] wrote:
>I am a new owner of an early K2 with Seriel No 638. Initialy rig worked
>fine, but now a random fault is occuring .
>
> I hear a couple of relay clicks (sometimes more) and the display rapidly
> changes and when stops, the message E137 0.26 or E138 0.26 is usualy
> given. On one occasion the display was left with St L 071. On other
> occasionns the display just appears random. Are these error codes, and if
> so could anyone give me their meaning. The push buttons are
> non-functional and I can only get back to operation by switching OFF , and
> then ON.
>
> To me, the symptoms are similar to my early computer experiences, when
> the computer went south. Any recommendations for trouble shooting would
> be appreciated.
>
> The last point is that the problem is chronic during warm up. After 15 to
> 20 mins the problem is either gone or significantly reduced in magnitude.
>
> Thank you, Colin M3WCK
_______________________________________________
Elecraft mailing list
Post to:
[hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
http://mailman.qth.net/mailman/listinfo/elecraft
Help:
http://mailman.qth.net/subscribers.htmElecraft web page:
http://www.elecraft.com