I have completed soldering the components for the K1 2 band filter
board, but when I performed the resistance checks, there was a
problem.

XX - U1 pin 6, U1 pin 7 230-270 ohms --- >100k
XX - U1 pin 6, U1 pin 8 230-270 ohms --- >100k
XX - U1 pin 6, U1 pin 12 230-270 ohms --- >100k
XX - U1 pin 13, P2 pin 6 90-110 ohms --- >100k
OK - P1 pin 1, P1 pin 3 > 100 k
OK - P1 pin 2, P1 pin 3 > 100 k
OK - P1 pin 3, P1 pin 4 > 100 k
OK - P1 pin 3, P1 pin 6 > 100 k
OK - P2 pin 1, P2 pin 2 > 100 k
OK - P2 pin 7, P2 pin 8 > 100 k
XX - K3 pin 2, K3 pin 9 < 5 ohms --- >100k
XX - K3 pin 4, K3 pin 7 < 5 ohms --- >100k

Basically, everything that but the P1 & P2 checks seemed well out of
range, like I have an open somewhere.  I guess an open is better than
a short!  I took the time to fix some weak looking solder points, but
that didn't fix it.

Does anyone on the list have any advice for troubleshooting this?  So
far, I've thought about trying a different meter :) and as I
mentioned, fixing up some solder points that didn't look so good.

High res photos here:

Bottom
http://picasaweb.google.com/joseph.durnal/ElecraftK1TransceiverBuild/photo#5063510917493130034

Top
http://picasaweb.google.com/joseph.durnal/ElecraftK1TransceiverBuild/photo#5063510883133391650

Thanks to all
73
Joe
NE3R
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com