Login  Register

Re: K3: S-meter calibration (redux)

Posted by Bill VanAlstyne W5WVO on Jun 07, 2007; 1:39pm
URL: http://elecraft.85.s1.nabble.com/K3-S-meter-calibration-redux-tp448734p448751.html

You guys are awesome!  :D

Bill / /W5WVO


wayne burdick wrote:

> On Jun 6, 2007, at 10:01 PM, Bill W5WVO wrote:
>
>> Hi Wayne,
>>
>> In addition to the slope of the function (dB per S-unit), is the
>> scale set point user-configurable? Or is this hard-coded such that
>> S9=50 uV?
>
> User settable.
>
> Wayne
>
>
> ---
>
> http://www.elecraft.com

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com