Michael Haygood wrote:
> Hi,
>
> I've been using my K2/100 for many months with great results.  After a
> recent storm containing lightning the next time I fired up the K2/100 I
> received the "HI CURR" message and the "HI REFL" messages upon initial
> transmit.  This was unusual, so the next thing I did was consult the
> troubleshooting guide in the KPA100.

I would check the t/r switch components, D11, 12, 13, and 14 as well as
Q6-Q7. If something is shorted it would load down the HV power supply.

Also diodes D16-17 in the power/swr bridge could be damaged.
--
73,
Vic, K2VCO
Fresno CA