http://elecraft.85.s1.nabble.com/K2-KSB2-T1-T2-Turns-Ratio-Question-tp6304006p6304037.html
passband flatness. This can vary with crystal characteristics, circuit
strays, etc.
> Hi Folks.
>
> I've been perplexed for quite some time as to why RF transformers T1
> and T2 that sit at opposite ends of the crystal ladder filter on the
> KSB2 board have different turns ratios.
>
> T1's turns ratio is 22:7. while T2's is 22:4.
>
> The impedance of the crystal ladder network appears to be in the
> neighborhood of 1200 - 1500 ohms. Since the KSB2 sits inside an IF
> having a 150 ohm impedance, T1's 22:7 turns ratio, which performs a
> 9.87:1 impedance transformation, makes perfect sense.
>
> The Balanced Modulator feeds T2's primary with an impedance close to
> 1200 ohms, which also makes perfect sense.
>
> However, T2's secondary, having only 4 turns, presents an output
> impedance significantly lower than the 150 ohm IF system it is
> feeding.
>
> What's the deal? :-)
>
> And I ask this question as I troubleshoot a "narrower than expected"
> crystal filter response. I'm curious whether the T2 impedance
> mismatch is intentional, or something else is going on that I'm not
> aware of.
>
> Any relevant enlightenment on the subject would be appreciated.
>
> Thanks.
>
>
> 73, de John, KD2BD
> K2/100 #3563
>
> ______________________________________________________________
> Elecraft mailing list
> Home:
http://mailman.qth.net/mailman/listinfo/elecraft> Help:
http://mailman.qth.net/mmfaq.htm> Post: mailto:
[hidden email]
>
> This list hosted by:
http://www.qsl.net> Please help support this email list:
http://www.qsl.net/donate.html