Re: K3 s-meter calibration parameters and flickering S1...
Posted by
KK7P on
May 30, 2011; 4:35pm
URL: http://elecraft.85.s1.nabble.com/K3-s-meter-calibration-parameters-and-flickering-S1-tp6418969p6419818.html
Hello John!
In ABS mode this is normal. It is a consequence of offsets the DSP is
doing to account for the settings of ATT and PRE, along with the method
used to pass S Meter information to the MCU.
73,
Lyle KK7P
> After the RF calibration, I re-did the S-meter calibration using the XG3,
> with the K3 in ABS mode,...
>
> BUT, when I disconnect the XG3, so nothing is connected to ANT1, the S1 bar
> flickers on and off.
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]