Posted by
Bruce Beford-2 on
Jun 09, 2011; 8:23pm
URL: http://elecraft.85.s1.nabble.com/K3-K3EXREF-K144REFLK-and-K144XV-tp6458532p6459475.html
Couldn't this be automated for those with the K3EXREF?
Since the K3EXREF is applying a "fudge factor" (technical term) based on the
instantaneous error of the 49 MHz TXCO, one could "simply" read the
correction and the front panel temp over a thermal "run". The data could
then be massaged (another techinal term) internally, to come up with the
tabular data needed. Yes?
Bruce, N1RX
Wayne, N6KR wrote:
> What we could do in a future release is provide a way for customers to
> manually generate and use 1-degree data. Call it "Method 4." It seems
> a bit onerous, but here's the idea: First, you'd put your K3 in the
> refrigerator long enough to get to 0C, or the desired low operating
> temp. Next, set the rig up with an accurate frequency counter
> connected to the output of the oscillator, and put the cover back on,
> or at least part of the way on (the freq counter cable has to come out
> at the back or side). Then, as the radio heats up, write down the
> oscillator frequencies for each 1-degree point. <snip>