Posted by
N5NA on
Oct 08, 2011; 4:31pm
URL: http://elecraft.85.s1.nabble.com/Sudden-K3-AGC-pop-off-after-adding-P3-tp6872073p6872784.html
This is a problem not only for HRD but any software in which the AGC
status is polled continuously. I frequently use CQ/X by NO5W and had
the same problem. Chuck turned off the AGC polling in CQ/X and the
problem no longer occurs. Of course, now the AGC status can't be shown
in his remote interface.
I sent Wayne, N6KR, a couple of log files from portmon back in July
showing what was happening but so far I haven't seen any updates on this.
73, Alan N5NA
> ------------------------------
>
> Message: 39
> Date: Sat, 08 Oct 2011 10:11:21 +0100
> From: David Honey<
[hidden email]>
> Subject: Re: [Elecraft] Sudden K3 AGC pop-off after adding P3
> To:
[hidden email]
> Message-ID:<
[hidden email]>
> Content-Type: text/plain; charset=ISO-8859-1; format=flowed
>
> Dan,
>
> This is a known issue with HRD used with the K3. It happens with me a
> few times a week with my K3+P3. Reducing the polling rate of the K3 in
> HRD may reduce the frequency of this issue, but it won't eliminate it.
> The choice seems to be either put up it, or stop using HRD. Simon Brown
> has handed over the reins of HRD development, so perhaps the new team
> can devote some time to investigating and fixing this.
>
> vy 73 de David M0DHO
>
>
> ------------------------------