Re: P3 and CW signal not aligned perfectly

Posted by Nr4c on
URL: http://elecraft.85.s1.nabble.com/P3-and-CW-signal-not-aligned-perfectly-tp7220640p7220728.html

On the P3 there is a menu function to calibrate the frequency.  Do this
and you can set it perfectly.

...bc

On Tue, 24 Jan 2012 07:07:52 -0800 (PST), N0SA wrote:

> I have a K3 with the P3 panadapter.
> When I properly tune a CW signal in and us the SPOT and CW indicator
> I
> notice that it is not centered in the P3 display. If I center it then
> it is
> off by about 30 Hz.
> It shows the same offset if I change filters and go to REV CW.
> My SHIFT is centered.
> Is this normal or do I need to check and adjust something?
> Thanks
> Larry Naumann  N0SA
>
>
> --
> View this message in context:
>
> http://elecraft.365791.n2.nabble.com/P3-and-CW-signal-not-aligned-perfectly-tp7220640p7220640.html
> Sent from the Elecraft mailing list archive at Nabble.com.
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[hidden email]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html

______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html