Login  Register

Re: PR-6 issue when QRO

Posted by vk4tux on Apr 30, 2012; 7:34pm
URL: http://elecraft.85.s1.nabble.com/PR-6-issue-when-QRO-tp7511705p7514795.html

Perhaps so if the relays were fast enough already, using the AG6K sb-220
design speedup key circuit (EBS) with Jennings RJ1A or Kilovac HC1 relays,
with the 12v reed input relay works nice at 2mS switch times, good for 35
wpm qsk.  I have this setup in one of mine and its very economical to
setup.;

http://www.somis.org/QSK922.html

http://www.somis.org/D-a-07B.jpg

Adrian ... vk4tux



-----Original Message-----
From: [hidden email]
[mailto:[hidden email]] On Behalf Of K7WIA
Sent: Tuesday, 1 May 2012 1:30 AM
To: [hidden email]
Subject: Re: [Elecraft] PR-6 issue when QRO

If it is slow relay switching,  this could be added to the switching ckt.

http://www.w6pql.com/relay_sequencer.htm

Ed K7WIA


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html