Login  Register

Re: KPA3 / KAT500 Remote Question

Posted by Joel Black-2 on May 27, 2012; 12:20pm
URL: http://elecraft.85.s1.nabble.com/KPA3-KAT500-Remote-Question-tp7556611p7556632.html

John,

RS232 has a reliability issue past 50'.  I have seen it work up to 60'
with DDS circuits using CAT5 as the conductor and RJ45-to-DB9 / DB25
connectors.  After that, all bets are off.

BTW, this is not anecdotal, this is my experience in the real world.

73,
Joel - W4JBB


On 5/26/2012 2:55 PM, WB9JPH wrote:

> Question . . . .
>
> My station is in a 2nd floor loft.
>
> The antenna coax cables come into the basement utility room and then up behind the plasterboard walls to my shack.
>
> Will I be able to put the KAT 500 and KPA 3 in the basement utility room and control them by snaking an RS232 cable from the shack to the utility room through the PVC pipe that contains my coax?
>
> If this will work are there any special considerations I need to be aware of?
>
> 73
> John
>
>
>
> ______________________________________________________________
> Elecraft mailing list
> Home: http://mailman.qth.net/mailman/listinfo/elecraft
> Help: http://mailman.qth.net/mmfaq.htm
> Post: mailto:[hidden email]
>
> This list hosted by: http://www.qsl.net
> Please help support this email list: http://www.qsl.net/donate.html
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html