Re: 2T Gen problem
Posted by
Don Wilhelm on
Nov 01, 2017; 6:50pm
URL: http://elecraft.85.s1.nabble.com/2T-Gen-problem-tp452848p7635589.html
Jeremy,
No, I am saying replace it with another 0.01uF.
What is suspected is that the one in your 2T-Gen is on the low side of
tolerance, and putting in one closer to the nominal value or slightly
higher may make it oscillate.
73,
Don W3FPR
On 11/1/2017 11:45 AM, Jeremy Jones wrote:
> Don,
>
> C2 is already .01uF. Are you suggesting I try a .1uF?
>
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]
This list hosted by:
http://www.qsl.netPlease help support this email list:
http://www.qsl.net/donate.htmlMessage delivered to