Posted by
k6dgw on
Aug 17, 2018; 6:48pm
URL: http://elecraft.85.s1.nabble.com/KPA-1500-Efficiency-As-A-Function-of-Input-Power-tp7644440p7644462.html
Well, only if you've figured out a way to divide by zero. [:-)
The term "amplifier efficiency" must have changed dramatically since I
worked in broadcast nearly a lifetime ago. Then, it was the ratio
[expressed as a percentage] of the RF power delivered to the 3 1/8"
hardline divided by the DC power supplied to the amplifier plate
circuit. Power to the filaments was generally excluded by manufacturers
seeking to have higher efficiency numbers. One 10 KW FM transmitter I
helped build used four 4-1000A's in parallel and the filament power was
600 watts. Efficiency, including filament power was just over 70%.
To measure the efficiency of a KPA1500 [or 500, or KXPA100, or KPA2] one
would measure the key down RF output and divide it by the key down DC
input power. If it was water-cooled, I suppose one should include the
input power to the pump(s), but no one ever did. SS amplifiers like the
KPA(1)500 probably run class AB<mumble> or its equivalent and have
substantial DC input power even at zero RF input.
RF output power vs RF input power defines the amplifer's transfer
function, not its efficiency.
73,
Fred ["Skip"] K6DGW
Sparks NV DM09dn
Washoe County
PS: I really don't recommend trying to get four parallel 4-1000A's to
work anything close to "well" at 90.7 MHz. Apparently, it seemed like a
good idea at the time. [:-)
On 8/17/2018 6:24 AM, Charlie T wrote:
> Think zero output with zero drive = zero efficiency.
> Apply some drive, read some output and the efficiency goes up from there.
>
> 73, Charlie k3ICH
>
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]
This list hosted by:
http://www.qsl.netPlease help support this email list:
http://www.qsl.net/donate.htmlMessage delivered to
[hidden email]