"The Elecraft KPA500 amplifier also works efficiently into a load SWR of 1.5:1"
Any such claim is at best misleading. There may be some 1.5:1 loads that that the KPA500 will be happy with but there are other 1.5:1 loads that it will object to, to the point of giving multiple PA DISS faults. 1.5:1 SWR does not define the load characteristics. A 1.5:1 load could be pure R or it could be a complex impedance. The efficiency, PA dissipation, and risk of fault trip are not defined by the SWR.
73,
Andy k3wyc