K2 Alignment and Test, Part II issues
Posted by
Don Schroder on
Sep 27, 2018; 12:14am
URL: http://elecraft.85.s1.nabble.com/K2-Alignment-and-Test-Part-II-issues-tp7645364.html
Hi folks,
Got to the subject location on my K2 kit #7818, and am having some difficulties with the tests. My frequency counter, when touched to the left side of trimmer capacitor C22, reads 3999.98 on the LCD. This makes me believe there is no problem with the frequency counter probe that I assembled.
On page 63, under *4 MHz Oscillator Calibration, I selected CAL FCTR, and the LCD displays a rapidly changing frequency between 185.~ to 188.~. It does not show a frequency of 12090 kHz suggested by the manual. This tells me I have a problem with the PLL Reference Oscillator (since the frequency counter probe appeared to be ok). I then decided to check voltages, and discovered that I am missing some +5v signals from U4 and U5.
Any suggestions on where to look next? I’d like to trace the 5v signals, but I don’t see how to do that using the schematics. I did measure voltages on the 8 pins of the Thermistor Board, they were all 0 volts! That didn’t seem right, either.
Appreciate any suggestions! Thanks!
Don, KE0PVQ
Sent from Mail<
https://go.microsoft.com/fwlink/?LinkId=550986> for Windows 10
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]
This list hosted by:
http://www.qsl.netPlease help support this email list:
http://www.qsl.net/donate.htmlMessage delivered to
[hidden email]