K2 Narrow Spaced DR Measurement
Posted by
John Oppenheimer on
Oct 29, 2018; 1:38pm
URL: http://elecraft.85.s1.nabble.com/K2-Narrow-Spaced-DR-Measurement-tp7645954.html
While evaluating a receiver design, a K2 Narrow Spaced Dynamic Range
measurement was performed to validate the test bench. The K2 plot is on
the page:
https://www.kn5l.net/newReceiverProject/plot-IMD/If the two line equations are used, the Noise floor is -138 dBm and 2kHz
dynamic range is 87 dB. These are close to the Sherwood values of -136
and 80. The K2 settings are my normal operation IF/AF BW settings, which
is a little narrower than the Sherwood measurement parameters.
The question is the low level IMD measurement points do not follow the
line equation. Is this expected?
Guess I need to order a $60 Mini-Circuits ZFSC-2-6+
John KN5L