* On 2019 16 Jun 18:50 -0500, Kidder, George wrote:
> Interesting data, Don.  I wonder if there is any information about
> resistance variations between soldered and crimped terminals.  One might
> think that, with stranded wire, even a good crimp connection might not
> solidly involve all of the strands, and might additionally deteriorate
> with time since oxygen could get between the strands.  A good solder job
> should wet the wire through and (additionally) exclude oxygen.  This
> wouldn't be easy to measure, for sure, but these engineers are cleaver
> people!

For what it is worth, the company I worked for prohibited the use of
soldered connectors for terminating bonding or power wiring.  Especially
with regard to bonding, dissipating any lightning strike energy through
a soldered connector could cause it to enough to melt the solder.  In
doing some microwave site upgrades I did pull out a previous generation
of bonding wiring that was soldered and some connectors had signs of
being heated since installation.

In my shack I use crimp connectors and a quality crimping tool with no
problems.

73, Nate, N0NB

--

"The optimist proclaims that we live in the best of all
possible worlds.  The pessimist fears this is true."

Web: https://www.n0nb.us  GPG key: D55A8819  GitHub: N0NB
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]