I checked the operating specs on two of my QRO amps. Not a KPA500.
2m-1500w PA using a MRF1K50 in class AB:
945w 1398w dc 67% eff 453w disp
1511w 1888w dc 80% eff 377w disp
2m-1200w PA using a MRFE6VP61K25H in class AB:
566w 1200w dc 47% eff 634w disp
1133w 1542w dc 73% eff 409w disp
less heat dissipated when running full power RF ouput.