Login  Register

KPA 500

Posted by ANDY DURBIN on Apr 10, 2020; 6:12pm
URL: http://elecraft.85.s1.nabble.com/KPA-500-tp7659606p7659627.html

"After transmitting at 200W the temperature slowly
rises above 60 degrees C, but the fan doesn't cut in. Does anyone know
if this is normal behavior and what temperatures I should expect to see?"

Nominal temperature for start of fan speed 1 is 50 deg C although my data for one test run showed several seconds at 50 deg C and fan not running.  It started running just before the temperature rose to 51 deg C.

60 deg C with fan not running is not normal.  60 deg C is the nominal temperature for start of fan speed 3.

73,
Andy, k3wyc


______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]