KPA 500
Posted by
ANDY DURBIN on
Apr 10, 2020; 6:12pm
URL: http://elecraft.85.s1.nabble.com/KPA-500-tp7659606p7659627.html
"After transmitting at 200W the temperature slowly
rises above 60 degrees C, but the fan doesn't cut in. Does anyone know
if this is normal behavior and what temperatures I should expect to see?"
Nominal temperature for start of fan speed 1 is 50 deg C although my data for one test run showed several seconds at 50 deg C and fan not running. It started running just before the temperature rose to 51 deg C.
60 deg C with fan not running is not normal. 60 deg C is the nominal temperature for start of fan speed 3.
73,
Andy, k3wyc
______________________________________________________________