Login  Register

Re: Elecraft K3s, etc. bonding

Posted by Rick Bates, NK7I on Apr 24, 2020; 6:18am
URL: http://elecraft.85.s1.nabble.com/Elecraft-K3s-etc-bonding-tp7659942p7660075.html

And in the meantime, lightning protection helps to reduce the noise and
risks of 'everyday' static noise sources like wind, snow, blowing dust
and even rain static.  HELPS, not removes.

Having (last fall) just installed a basic dissipation system, the
difference can be quite startling and can allow one to hear a LOT
better.  My noise floor also dropped from 10-35 dB with an average of 20
dB the moment I tied it into the existing house safety grounds.  And
that was not only increased safety but was cheaper than most low band
reception arrays (which I'll add as well). 'New' DX; SCORE!

Just as any other station feature, one can continue to enhance or
upgrade lightning protection and bonding over time until there is less
return than cost expended.

One more often forgotten note:  ALL wiring coming into a building, must
be bonded to the common safety ground; satellite dishes, telephone/DSL
wires, cable TV... ALL of them or lightning will 'find a way' to ruin
your day.

Rick NK7I


On 4/23/2020 10:44 PM, Vic Rosenthal wrote:
> Serious lightning protection is something else, and can be very expensive. But although bonding the equipment won’t protect you against direct lightning strikes, it does help to keep everything at the same potential and reduce the possibility of damage from less violent static discharges.
>
> Victor 4X6GP
>  
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Message delivered to [hidden email]