AGC question

classic Classic list List threaded Threaded
3 messages Options
Reply | Threaded
Open this post in threaded view
|

AGC question

Larry Naumann
I am building a K2 and when I try to adjust the AGC voltage the most I can get is just under 3.8 volts, about 3.7 is what I can get. Is this okay or do I have a problem somehwere?
Thanks
Larry
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: AGC question

Don Wilhelm-4
Larry,

This is a frequently asked question - and it occurs when the 8 volt
supply rail is on the low side of its tolerance range.  If you cannot
get it up to 3.8, then leave it set at the highest setting.

73,
Don W3FPR

Larry Naumann wrote:
> I am building a K2 and when I try to adjust the AGC voltage the most I can get is just under 3.8 volts, about 3.7 is what I can get. Is this okay or do I have a problem somehwere?
> Thanks
> Larry
>
>  
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com

Reply | Threaded
Open this post in threaded view
|

Re: AGC question

David Woolley (E.L)
In reply to this post by Larry Naumann
Larry Naumann wrote:
> I am building a K2 and when I try to adjust the AGC voltage the most
> I can get is just under 3.8 volts, about 3.7 is what I can get. Is
> this okay or do I have a problem somehwere?

No problem.  The value quoted in the manual isn't actually achievable
for some combinations of component tolerances.  Originally the preset
was fixed, and they've quoted the nominal voltage when it is set to maximum.

--
David Woolley
Emails are not formal business letters, whatever businesses may want.
RFC1855 says there should be an address here, but, in a world of spam,
that is no longer good advice, as archive address hiding may not work.
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com