Hi cur on 6 meter

classic Classic list List threaded Threaded
3 messages Options
Reply | Threaded
Open this post in threaded view
|

Hi cur on 6 meter

Max iw0gxy
Today I've noted the HI CUR warning on my K3.
The vswr is very low (around 1.2) and the supply is 50A, so is not a supply overload question neither vswr problem (i checked also on dummy).
It happens when on 6m (and only on this band) the power is more than 84W. I updated the firmware when it has been released but actually i didn't noted if it happened with previous firmware releases.
Max IW0GXY
Reply | Threaded
Open this post in threaded view
|

Re: Hi cur on 6 meter

Max iw0gxy
I checked and the ammeter read 24A on 6mt@100W and 18A on other bands. So it's an unusual current drain.
Any hints?
Reply | Threaded
Open this post in threaded view
|

Re: Hi cur on 6 meter

Enno, PF5X
In reply to this post by Max iw0gxy
Hi Max,

It seems that the KPA3 is not as efficient on 6m as on the other bands. My K3 draws 21.5A at 6m/100W.
A friend of mine who owns a K3 complained about this phenomenon as well (25% more current on 6 than on other bands).

Maybe the design team can explain this behavior ...

-- Enno, PF5X

Max iw0gxy wrote
Today I've noted the HI CUR warning on my K3.
The vswr is very low (around 1.2) and the supply is 50A, so is not a supply overload question neither vswr problem (i checked also on dummy).
It happens when on 6m (and only on this band) the power is more than 84W. I updated the firmware when it has been released but actually i didn't noted if it happened with previous firmware releases.
Max IW0GXY