I am having problems with the 50 watt TX Gain Calibration, it shows 0
watts and gives the error "ERR TXG". The Low-Power 5 watt test worked fine and have low power output. Anyone had and resolved this problem? Running FW 1.88 Thanks, Joe N9VX K3 #841 _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
|
Have you initialized the PA in the menu and turned the rig off and on
a couple of times? Dave Wilburn K4DGW K2/100 - S/N 5982 K3/100 - S/N 766 "For those who fought for it, freedom has a flavor the protected will never know." Joe Word wrote: > I am having problems with the 50 watt TX Gain Calibration, it shows 0 > watts and gives the error "ERR TXG". The Low-Power 5 watt test > worked fine and have low power output. > > Anyone had and resolved this problem? > > Running FW 1.88 > > Thanks, > > Joe N9VX > > K3 #841 > _______________________________________________ > Elecraft mailing list > Post to: [hidden email] > You must be a subscriber to post to the list. > Subscriber Info (Addr. Change, sub, unsub etc.): > http://mailman.qth.net/mailman/listinfo/elecraft > > Help: http://mailman.qth.net/subscribers.htm > Elecraft web page: http://www.elecraft.com > Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
|
In reply to this post by Joe Word
Dave, PA is set to nor and have turned off/on multiple times.
Just checked the Circuit Breaker, it's making contact. Joe Dave wrote.. Have you initialized the PA in the menu and turned the rig off and on a couple of times? Dave Wilburn ----------------------------------------------------------------------------------------- ---------- Forwarded message ---------- From: Joe Word <[hidden email]> Date: May 13, 2008 11:28 AM Subject: K3: High-Power TX Gain Calibration - No Output To: [hidden email] I am having problems with the 50 watt TX Gain Calibration, it shows 0 watts and gives the error "ERR TXG". The Low-Power 5 watt test worked fine and have low power output. Anyone had and resolved this problem? Running FW 1.88 Thanks, Joe N9VX K3 #841 _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
|
I would next open up the K3 update tool, and under the Configuration
tab, select the click on the Edit Crystal Filters... button. In what ever mode you were getting the TX error on, ensure that one of buttons on the bottom 4 (including FM if applicable) lines is selected for that mode. As an example, in my case, the 2.70 filter is selected for Tx CW, Tx SSB, and Tx AM. Dave Wilburn K4DGW K2/100 - S/N 5982 K3/100 - S/N 766 "For those who fought for it, freedom has a flavor the protected will never know." Joe Word wrote: > Dave, PA is set to nor and have turned off/on multiple times. > Just checked the Circuit Breaker, it's making contact. > > Joe > > Dave wrote.. > Have you initialized the PA in the menu and turned the rig off and on > a couple of times? > > > Dave Wilburn > > > ----------------------------------------------------------------------------------------- > > ---------- Forwarded message ---------- > From: Joe Word <[hidden email]> > Date: May 13, 2008 11:28 AM > Subject: K3: High-Power TX Gain Calibration - No Output > To: [hidden email] > > > I am having problems with the 50 watt TX Gain Calibration, it shows 0 > watts and gives the error "ERR TXG". The Low-Power 5 watt test > worked fine and have low power output. > > Anyone had and resolved this problem? > > Running FW 1.88 > > Thanks, > > Joe N9VX > > K3 #841 > _______________________________________________ > Elecraft mailing list > Post to: [hidden email] > You must be a subscriber to post to the list. > Subscriber Info (Addr. Change, sub, unsub etc.): > http://mailman.qth.net/mailman/listinfo/elecraft > > Help: http://mailman.qth.net/subscribers.htm > Elecraft web page: http://www.elecraft.com > Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |
|
In reply to this post by Joe Word
I fixed the problem. Removed KPA3 and found a gray wire out of T1, at
the C1 end, was under the mounting bracket (KPA3 to RF Shield). The K3 now puts out full power and the High Power Gain Calibration is complete for all bands. Thanks Gary at Elecraft for the excellent help. And thanks to all of you for your comments and suggestions. What a nice receiver!!! 73, Joe N9VX ---------- Forwarded message ---------- From: Joe Word <[hidden email]> Date: May 13, 2008 11:28 AM Subject: K3: High-Power TX Gain Calibration - No Output To: [hidden email] I am having problems with the 50 watt TX Gain Calibration, it shows 0 watts and gives the error "ERR TXG". The Low-Power 5 watt test worked fine and have low power output. Anyone had and resolved this problem? Running FW 1.88 Thanks, Joe N9VX K3 #841 _______________________________________________ Elecraft mailing list Post to: [hidden email] You must be a subscriber to post to the list. Subscriber Info (Addr. Change, sub, unsub etc.): http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/subscribers.htm Elecraft web page: http://www.elecraft.com |