Can anyone throw any light on the following way in which my K3 has always behaved?

Using memories 00 - 09 as if they were band switches: Config: Mem 0-9 : Band Sel
Memories 00 - 09 are each set up on a frequency in each band using the V>M button.
Tap M>V button, then select a memory either by rotating VFO A or by tapping buttons 0 - 9, then tap M>V again.
Band is selected correctly but VFO A is locked up and won't change frequency until another button is pushed (e.g. Freq Ent, Fine or Rate)

It's not a major problem but am I doing something wrong?

73
Tom G3OLB
K3 S/N: 01434 with FW v. 3.97
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:[hidden email]

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: K3 Memory Recall

Mike K2MK
Hi Tom:

I troubleshoot peculiar K3 occurrences in this order.
1. Operator error
2. Computer error
3. K3 error

It sounds like item 1 is ok. Move to item 2. Turn off any logging program or better yet disconnect the serial cable.

73,
Mike K2MK



Tom Boucher wrote
Can anyone throw any light on the following way in which my K3 has always behaved?

Using memories 00 - 09 as if they were band switches: Config: Mem 0-9 : Band Sel
Memories 00 - 09 are each set up on a frequency in each band using the V>M button.
Tap M>V button, then select a memory either by rotating VFO A or by tapping buttons 0 - 9, then tap M>V again.
Band is selected correctly but VFO A is locked up and won't change frequency until another button is pushed (e.g. Freq Ent, Fine or Rate)

It's not a major problem but am I doing something wrong?

73
Tom G3OLB
K3 S/N: 01434 with FW v. 3.97
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html
Reply | Threaded
Open this post in threaded view
|

Re: K3 Memory Recall

WB8ENE
In reply to this post by Tom Boucher
Sounds like you have a * in the first position of the name for that memory location.

73,
Art WB8ENE
Reply | Threaded
Open this post in threaded view
|

Re: K3 Memory Recall

ab2tc
In reply to this post by Tom Boucher
Hi,

Don't hit the M>V button again! Band changes as soon as you hit the number button.

AB2TC - Knut

Tom Boucher wrote
Can anyone throw any light on the following way in which my K3 has always behaved?

Using memories 00 - 09 as if they were band switches: Config: Mem 0-9 : Band Sel
Memories 00 - 09 are each set up on a frequency in each band using the V>M button.
Tap M>V button, then select a memory either by rotating VFO A or by tapping buttons 0 - 9, then tap M>V again.
Band is selected correctly but VFO A is locked up and won't change frequency until another button is pushed (e.g. Freq Ent, Fine or Rate)

It's not a major problem but am I doing something wrong?

73
Tom G3OLB
K3 S/N: 01434 with FW v. 3.97
______________________________________________________________
Elecraft mailing list
Home: http://mailman.qth.net/mailman/listinfo/elecraft
Help: http://mailman.qth.net/mmfaq.htm
Post: mailto:Elecraft@mailman.qth.net

This list hosted by: http://www.qsl.net
Please help support this email list: http://www.qsl.net/donate.html