I seem to be suffering a recurrence of a very old problem (years ago) for
which I don't recall the solution: I have a real K3 at the control site, controlling a K3 at the remote site via RRC-1258 MkII boxes. I have a mechanical D-SUB 9 pin switch to route the control site K3 serial port to either a local computer or the RRC. When routed to the RRC and operating normally, when I turn on the K3 it begins to show its power-on banner in the VFO B area, then mid-way through that scroll detects that it's in TERM mode with an RRC connected, powers up the remote K3, and all is well. However, that doesn't seem to be working now. The control K3 comes up and fails to detect the RRC. The power-on banner for the control K3 completes its scroll and the radio operates locally. I think it is slipping out of TERM mode. I can force it back into TERM mode with a long hold of the CONFIG button, but then it never turns on the remote radio. If I turn off the control K3 and then back on, it apparently has forgotten it was in TERM mode. Any advice? Thanks, /Rick N6XI -- Rick Tavan Truckee, CA ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
I've experienced this several times Rick. Once, it was because I had
dismantled my control setup and when I reassembled it, I forgot to use the null modem cable between the K3 and RRC. The other times [three maybe], it's been a bad RS-232 DE-9 connection at the RRC. I think it is only one pin ... apparently all DE-9 jumpers are not created equal. I use a mechanical A/B switch too. 73, Fred ["Skip"] K6DGW Sparks NV DM09dn Washoe County On 8/30/2018 10:50 AM, Rick Tavan wrote: > I seem to be suffering a recurrence of a very old problem (years ago) for > which I don't recall the solution: > > I have a real K3 at the control site, controlling a K3 at the remote site > via RRC-1258 MkII boxes. I have a mechanical D-SUB 9 pin switch to route > the control site K3 serial port to either a local computer or the RRC. When > routed to the RRC and operating normally, when I turn on the K3 it begins > to show its power-on banner in the VFO B area, then mid-way through that > scroll detects that it's in TERM mode with an RRC connected, powers up the > remote K3, and all is well. However, that doesn't seem to be working now. > The control K3 comes up and fails to detect the RRC. The power-on banner > for the control K3 completes its scroll and the radio operates locally. I > think it is slipping out of TERM mode. I can force it back into TERM mode > with a long hold of the CONFIG button, but then it never turns on the > remote radio. If I turn off the control K3 and then back on, it apparently > has forgotten it was in TERM mode. > > Any advice? > > Thanks, > > /Rick N6XI > -- > > Rick Tavan > Truckee, CA > ______________________________________________________________ > ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
In reply to this post by Rick Tavan-2
Hey Rick,
The TERM message should always be transitory. If it is not, you have an RS-232 control problem (like the null-modem issue). Check all your cables. In 100% of the times I've seen this issue, it's a loose connector or a mismatched cable 73 Gerry Hull, W1VE Hancock, NH USA Trustee, VY1AAA YT Remote On Thu, Aug 30, 2018 at 1:50 PM Rick Tavan <[hidden email]> wrote: > I seem to be suffering a recurrence of a very old problem (years ago) for > which I don't recall the solution: > > I have a real K3 at the control site, controlling a K3 at the remote site > via RRC-1258 MkII boxes. I have a mechanical D-SUB 9 pin switch to route > the control site K3 serial port to either a local computer or the RRC. When > routed to the RRC and operating normally, when I turn on the K3 it begins > to show its power-on banner in the VFO B area, then mid-way through that > scroll detects that it's in TERM mode with an RRC connected, powers up the > remote K3, and all is well. However, that doesn't seem to be working now. > The control K3 comes up and fails to detect the RRC. The power-on banner > for the control K3 completes its scroll and the radio operates locally. I > think it is slipping out of TERM mode. I can force it back into TERM mode > with a long hold of the CONFIG button, but then it never turns on the > remote radio. If I turn off the control K3 and then back on, it apparently > has forgotten it was in TERM mode. > > Any advice? > > Thanks, > > /Rick N6XI > -- > > Rick Tavan > Truckee, CA > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Message delivered to [hidden email] > Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html Message delivered to [hidden email] |
Free forum by Nabble | Edit this page |