Gang,
I am in the midst of putting together the KX1. I am at the first intermission where a few resistance checks are performed. So, in one of these tests, it says that resistance checks of all other pings of U1 (other then those explicitly measured already) should have resistance greater then 10K ohms. Well, for almost every other pin, the resistance I measure is not only greater then 10K but greater then 2 to 4 Meg ohms. I assume this is OK since it satisfies the constraint. Is this a reasonable assumption? For the D2 and D3 cathode resistance measurements I also read very high, multi Meg ohm values, for a constraint specified as > 1 K ohm. I have made measurements with S1 open and closed per the tests. My measurements always agree to the stated constraint (e.g. > 1 K and > 10 K) but I measure very large resistance values in the meg ohm range. Is this reasonable? Thanks for any comments or suggestions. 73, phil, K7PEH ______________________________________________________________ Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
I don't rank in the super-extreme expert level with the KX1, but I've built
a few and believe that should be all fine. 73! Steve, KW4H On Sun, Sep 5, 2010 at 11:49 PM, Phil Hystad <[hidden email]> wrote: > Gang, > > I am in the midst of putting together the KX1. I am at the first > intermission where a few resistance checks are performed. > > So, in one of these tests, it says that resistance checks of all other > pings of U1 (other then those explicitly measured already) should have > resistance greater then 10K ohms. Well, for almost every other pin, the > resistance I measure is not only greater then 10K but greater then 2 to 4 > Meg ohms. I assume this is OK since it satisfies the constraint. Is this a > reasonable assumption? > > For the D2 and D3 cathode resistance measurements I also read very high, > multi Meg ohm values, for a constraint specified as > 1 K ohm. I have made > measurements with S1 open and closed per the tests. My measurements always > agree to the stated constraint (e.g. > 1 K and > 10 K) but I measure very > large resistance values in the meg ohm range. Is this reasonable? > > Thanks for any comments or suggestions. > > 73, phil, K7PEH > > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
In reply to this post by Phil Hystad-3
Phil,
Greater than is defined as "greater than" - it can be as high as infinite = totally open circuit. The manual values consider that different DMMs will read resistances differently - particularly open circuit values. 73, Don W3FPR On 9/5/2010 11:49 PM, Phil Hystad wrote: > Gang, > > I am in the midst of putting together the KX1. I am at the first intermission where a few resistance checks are performed. > > So, in one of these tests, it says that resistance checks of all other pings of U1 (other then those explicitly measured already) should have resistance greater then 10K ohms. Well, for almost every other pin, the resistance I measure is not only greater then 10K but greater then 2 to 4 Meg ohms. I assume this is OK since it satisfies the constraint. Is this a reasonable assumption? > > For the D2 and D3 cathode resistance measurements I also read very high, multi Meg ohm values, for a constraint specified as> 1 K ohm. I have made measurements with S1 open and closed per the tests. My measurements always agree to the stated constraint (e.g.> 1 K and> 10 K) but I measure very large resistance values in the meg ohm range. Is this reasonable? > > Thanks for any comments or suggestions. > > 73, phil, K7PEH > > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
Free forum by Nabble | Edit this page |