On Fri, 2011-01-14 at 10:10 -0500, Roy Morris wrote:
> I have noticed the signal strength in S units on the P3 is lower than the S meter (in peak mode) on the K3. Is this normal? Thanks. Roy Morris W4WFB
It depends on how much lower. It ought to be within an S-unit or so.
If it's an older K3 that does not have the IF output modification, then
the P3 would read low by 10 dB-ish (a couple S-units).
http://www.elecraft.com/K3/mods/IF_Output_Buffer_Gain_Mod_Rev_A.pdfYou can calibrate the P3 amplitude so it matches the K3 using the menu
item MENU:Lvl Cal.
Alan N1AL
______________________________________________________________
Elecraft mailing list
Home:
http://mailman.qth.net/mailman/listinfo/elecraftHelp:
http://mailman.qth.net/mmfaq.htmPost: mailto:
[hidden email]
This list hosted by:
http://www.qsl.netPlease help support this email list:
http://www.qsl.net/donate.html