Re: K2 & ESD

bill KE5KWE
I am building my K2 s/n 6301 in my Travel Trailer.  I
have plugged my esd wrist strap and pad into the
ground port of a GFCI outlet.  I think this is my only
true ground, assuming that the Camp Ground post is
properly grounded.  All of my test quipment say the
post is wired properly as well as the outlet.  Any one
know, if I am correct?

Thanks,

Bill KE5KWE


      ____________________________________________________________________________________
Never miss a thing.  Make Yahoo your home page.
http://www.yahoo.com/r/hs

_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com
Reply | Threaded
Open this post in threaded view
|

Re: Re: K2 & ESD

Don Wilhelm-4
Bill,

I believe folks are worrying too much about a 'true earth ground' when
considering ESD - it is actually only necessary that everything at the
workspace (including the worker) is at the same potential - it matters
not whether that potential is at Mother Earth Ground potential or
hundreds of volts above it.

So pick a common point (and the travel trailer wiring ground lug should
be good), and connect your wrist strap and anti-static mat cords to
that, and plug your anti-static soldering station into the same outlet.

If there is a fault in the grounding of that electrical post, it can
pose a hazard for you or your family or pets when you touch the trailer
and Mother Earth Ground at the same time, but that is a different story
altogether - it has nothing to do with ESD protection inside an isolated
structure such as a travel trailer.

73,
Don W3FPR

Bill Fogel wrote:

> I am building my K2 s/n 6301 in my Travel Trailer.  I
> have plugged my esd wrist strap and pad into the
> ground port of a GFCI outlet.  I think this is my only
> true ground, assuming that the Camp Ground post is
> properly grounded.  All of my test quipment say the
> post is wired properly as well as the outlet.  Any one
> know, if I am correct?
>
> Thanks,
>
> Bill KE5KWE
>
>
>       ____________________________________________________________________________________
> Never miss a thing.  Make Yahoo your home page.
> http://www.yahoo.com/r/hs
>
> _______________________________________________
> Elecraft mailing list
> Post to: [hidden email]
> You must be a subscriber to post to the list.
> Subscriber Info (Addr. Change, sub, unsub etc.):
>  http://mailman.qth.net/mailman/listinfo/elecraft   
>
> Help: http://mailman.qth.net/subscribers.htm
> Elecraft web page: http://www.elecraft.com
>
>
>  
_______________________________________________
Elecraft mailing list
Post to: [hidden email]
You must be a subscriber to post to the list.
Subscriber Info (Addr. Change, sub, unsub etc.):
 http://mailman.qth.net/mailman/listinfo/elecraft   

Help: http://mailman.qth.net/subscribers.htm
Elecraft web page: http://www.elecraft.com
Reply | Threaded
Open this post in threaded view
|

RE: Re: K2 & ESD

AC7AC
In reply to this post by bill KE5KWE
CONTENTS DELETED
The author has deleted this message.