Hello all,
When attempting to calibrate my K2's S-meter with a XG1, I discovered the XG1 itself is having a problem. I verified this by connecting it to a working IC-7600. The signal output on it, although heard, is very weak. Adjusted for on-frequency, the s-meter reads about S2 or S3. Touching the XG1 can get the signal up to about S4 or S5. Switching between 1 uV and 50 uV makes no apparent difference in signal strength on the s-meter. Resistance checks on the XG1 and found some problems: Resistance from the following junctions to ground: U2, R1 = 50 k Ohms (should be 57-63 k Ohms) C4, R3 = 50 k Ohms (should be 57-63 k Ohms) R1, C1 = 54 k Ohms (should be 67-73 k Ohms) Checked all component placements and solder joints, no obvious problems. Reheated all solder joints (twice now) just in case; no improvement. My next step is to measure all the resistor and capacitor values. Do these symptoms jump out anybody as something obvious (bad xtal or other component)? Any suggestions will be most appreciated. 73 Brian - N5BCN |
Brian,
Those resistances are close, but admittedly a bit on the low side - but not enough to declare those the root of your problem. Your description sounds like you get the 1 uV output no matter which position the switch is in. The attenuator consisting of R6, R7 and R8 should be out of the circuit when in the 50 uV position. Examine the schematic and check the switch for proper operation. The schematic shows the switch in the 50 uV position. If the attenuator is in all the time, you will have only a 1 uV signal level. If you are having trouble following the schematic, then measure the resistance from the junction of R4 and R5 to the junction of R6 and R8 when the switch is in the 50 uV position - the resistance should be very high. If it is not, look for solder splashes (and excess solder) or the possibility of a bad switch. 73, Don W3FPR Brian - N5BCN wrote: > Hello all, > > When attempting to calibrate my K2's S-meter with a XG1, I discovered the > XG1 itself is having a problem. I verified this by connecting it to a > working IC-7600. > > The signal output on it, although heard, is very weak. Adjusted for > on-frequency, the s-meter reads about S2 or S3. Touching the XG1 can get > the signal up to about S4 or S5. Switching between 1 uV and 50 uV makes no > apparent difference in signal strength on the s-meter. > > Resistance checks on the XG1 and found some problems: > > Resistance from the following junctions to ground: > > U2, R1 = 50 k Ohms (should be 57-63 k Ohms) > C4, R3 = 50 k Ohms (should be 57-63 k Ohms) > R1, C1 = 54 k Ohms (should be 67-73 k Ohms) > > Checked all component placements and solder joints, no obvious problems. > Reheated all solder joints (twice now) just in case; no improvement. > > My next step is to measure all the resistor and capacitor values. > > Do these symptoms jump out anybody as something obvious (bad xtal or other > component)? Any suggestions will be most appreciated. > > 73 > > Brian - N5BCN > > Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
Hi Don,
The resistance from R4/R5 junction to R6/R8 junction with switch at 50 uV is about 104 Ohms. The value with the switch at 1 uV is 0.1 Ohms. 104 Ohms isn't "very high," perhaps a bad or dirty switch? No solder bridges visible around the switch. Is there an easy way to clean it without removing it from the PCB? Thanks. Brian - N5BCN |
In reply to this post by Brian - N5BCN
Check to make sure you haven't transmitted into the XG1 and blown the
safety diode. You can easily remove it to see. On Mon, Nov 23, 2009 at 4:40 PM, Brian - N5BCN <[hidden email]> wrote: > > Hello all, > > When attempting to calibrate my K2's S-meter with a XG1, I discovered the > XG1 itself is having a problem. I verified this by connecting it to a > working IC-7600. > > The signal output on it, although heard, is very weak. Adjusted for > on-frequency, the s-meter reads about S2 or S3. Touching the XG1 can get > the signal up to about S4 or S5. Switching between 1 uV and 50 uV makes no > apparent difference in signal strength on the s-meter. > > Resistance checks on the XG1 and found some problems: > > Resistance from the following junctions to ground: > > U2, R1 = 50 k Ohms (should be 57-63 k Ohms) > C4, R3 = 50 k Ohms (should be 57-63 k Ohms) > R1, C1 = 54 k Ohms (should be 67-73 k Ohms) > > Checked all component placements and solder joints, no obvious problems. > Reheated all solder joints (twice now) just in case; no improvement. > > My next step is to measure all the resistor and capacitor values. > > Do these symptoms jump out anybody as something obvious (bad xtal or other > component)? Any suggestions will be most appreciated. > > 73 > > Brian - N5BCN > > ----- > K2 #6800 KSB2 KAT2 KIO2 KNB2 > -- > View this message in context: http://n2.nabble.com/XG1-signal-problem-tp4054195p4054195.html > Sent from the [MM] mailing list archive at Nabble.com. > ______________________________________________________________ > Elecraft mailing list > Home: http://mailman.qth.net/mailman/listinfo/elecraft > Help: http://mailman.qth.net/mmfaq.htm > Post: mailto:[hidden email] > > This list hosted by: http://www.qsl.net > Please help support this email list: http://www.qsl.net/donate.html > Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
In reply to this post by Brian - N5BCN
Brian,
I would advocate removing the switch from the PC board and see if the resistance goes higher - in theory, it should be infinite. I don't know of an easy way - sorry. It may be the switch, or it could be the diodes in the output, but something is not right if you measured 104 ohms with the switch in the 50 uV position. 73, Don W3FPR Brian - N5BCN wrote: > Hi Don, > > The resistance from R4/R5 junction to R6/R8 junction with switch at 50 uV is > about 104 Ohms. The value with the switch at 1 uV is 0.1 Ohms. 104 Ohms > isn't "very high," perhaps a bad or dirty switch? No solder bridges visible > around the switch. > > Is there an easy way to clean it without removing it from the PCB? > > Thanks. > > Brian - N5BCN > > ----- > K2 #6800 KSB2 KAT2 KIO2 KNB2 > > Elecraft mailing list Home: http://mailman.qth.net/mailman/listinfo/elecraft Help: http://mailman.qth.net/mmfaq.htm Post: mailto:[hidden email] This list hosted by: http://www.qsl.net Please help support this email list: http://www.qsl.net/donate.html |
In reply to this post by Brian - N5BCN
Brian,
I had a similar problem off and on with my XG1 for 2-3 years. While recently calibrating the S meter in my new K3 it came to the point I could no longer use it. During troubleshooting as you did I found that tapping the case of X1 (crystal case) would cause the problem to come and go. I installed a replacement crystal from Elecraft and no longer had the problem. I also replaced the variable cap at the same time as a tiny piece of insulation was sticking out from the edge of the top metal plate under the adjustment screw. If troubleshooting doesn't find another problem you might replace the crystal and/or variable cap to see what happens. Have a good day and 73, Jim, W0EM
|
Free forum by Nabble | Edit this page |